What was found
CORROSION ON BS 277 LBL 40-LBL45 WL 208 LATERAL UPPER SURFACE CHORD ANGLE<[01] NO ALLOWABLE LIMITS FOUND ON SRM DAMAGE REMOVED PER SRM 51-10-02-0G-0 5'X1' AREA ORIGINAL MATERIAL THICKNESS IS 0.100' REMAINING LOWEST MATERIAL THICKNESS IS 0.062' SUBMMITED INFORMATION TO ENGINEERING TO FURTHER REPAIR INSTRUCTIONS;[02] TOOL USED ON CORRECTIVE ACTION 1<BR>ATS1225<BR>DUE 08/2023<BR>ATS2883<BR>DUE 04/2024;[03] VERIFIED CORRECTIVE ACTIONS 1 AND 2<BR><BR>VERIFIED MEASUREMENTS TABLE;[04] REPAIRED PER EA 23-153-02148. THIS IS A CATEGORY A REPAIR AS DEFINED IN BOEING 737-700 SRM 51-00-06.;[05] VERIFIED RII REQUIREMENTS COMPLETED.;[06] VERIFIED CORRECTIVE ACTION ITEMS AND MEASUREMENT FIELDS; CARD COMPLETE.