What was found
CORROSION ON FSD THRESHOLD SUPPORT BS312+3 RBL54 WL208.<[01] VERIFIED APLICABILITTY OF SRM 53-10-15-1A-2;[02] REMOVED CORROSION OF FWD SERVICE DOOR MOPSILL THRESHOLD ATTACH ANGLE BS 312+3; RBL54; WL 208 1'X1'AREA AND FOUND OUT LIMITS; MATERIAL THICKNESS 0.090' REMOVED MATERIAL 0.012' REMAINING THICKNESS 0.078' IAW SRM 53-10-15-1A-2; 53-10-15-0I-2 PART TO BE REMOVE AND REPLACE I.A.W SRM 51-10-02-0G-0 PAR 9.A(1)<BR>TOOL USED <BR>ATS 1225 DUE DATE <BR>08/2023 AND <BR>ATS2883 <BR>DUE DATE 04/2024.;[03] VERIFIED CORRECTIVE ACTIONS 1 AND 2.;[04] REMOVED FSD THRESHOLD SUPPORT MOPSILL ATTACH ANGLE AND DRILLED NEW I.A.W SRM 51-40-02-0G-0;SRM 51-40-05-0G-0 AND BOEING DWG 141A8310.OK TO INSTALL;[05] VERIFIED CORRECTIVE ACTION #4;[06] INSTALLED FSD THRESHOLD SUPPORT MOPSILL ATTACH ANGLE I.A.W SRM 51-40-02-0G-0 AND BOEING DWG 141A8310.;[07] VERIFIED CORRECTIVE ACTION 6;[08] VERIFIED MEASUREMENT TABLE