What was found
CORROSION ON FWD CARGO BAY DOOR CUT-OUT AFT SHIELD AT STA: 500+6 & 500+10; WL 156; RBL 24.5.<[01] COMPLETED STEP 1.;[02] VERIFIED CORRECTIVE ACTION ITEM 1.;[03] UPDATED MEASUREMENT TABLE.;[04] UPDATED STEPS 2 AND 3.;[05] EDIT TO STEP 3; NOW HAS CORRECT REFERENCE.;[06] UPDATED STEP 2;4;5;AND 6;[07] NO SRM ALLOWABLE DAMAGE WAS FOUND TO BE APPLICABLE. REPAIR BY REMOVAL AND REPLACEMENT OF PART IAW SRM 51-10-02-0G-0 9.C.<BR><BR>REMOVED FWD CARGO BAY DOOR CUT-OUT SHIELD IAW SRM 51-40-02-0G-0.<BR><BR>LOCATE AND DRILLED NEW FWD CARGO BAY DOOR CUT-OUT SHIELD IAW SRM 51-40-05-0G-0 AND DWG 143A0080.<BR><BR>APPLIED CHEMICAL CONVERSION COATING AND PRIMER IAW SRM 51-20-01-0G-0 AND SOPM 20-41-02<BR><BR>APPLIED BMS 10-11 TYPE 2 ENAMEL COATING IAW SOPM 20-41-02<BR><BR>INSTALLED NEW FCB DOOR CUTOUT SHIELD IAW SRM 51-40-02-0G-0 AND DWG 143A0080 ID:0023 REV:-;[08] VERIFIED CORRECTIVE ACTION #7<BR>VERIFIED MEASUREMENTS