What was found
MID CABIN FLOOR PANEL 242AF HAS PULLED COMPOSITE FIBERS ON UPPER SURFCE. CLEANED FLOORBOARD IAW SRM 53-0-50-2R-0 REPAIR GENERAL PARAGRAPH 5 A (1). ACCOMPLISHED UT IAW NDT PART 4 51-00-05. NO DISBOND NOTED. ACCOMPLISHED UT IAW NDT PART 4 51-00-03. NO WATER INTRUSION NOTED. VERIFIED NO EXPOSED WIRING IAW EA 25-153-02687-WIP1. STEP 1 COMPLETE. REMOVED DAMAGE; PREPPED AND APPLIED POTTING COMPOUND IAW SRM 53-00-50-2R-1 PARAGRAPH 3A - 3J. STEP 2 ACCOMPLISHED REF. EA 23-153-02687-WIP1. BONDED REPAIR IAW SRM 53-00-50-2R-1 PARAGRAPH 3K - 3M. REPAIRED DAMAGE TO FLOORBOARD IAW SRM 53-0-50-2R-0 REPAIR GENERAL; SRM 53-00-50-2R-1 REPAIR 1 AND EA 23-153-02687.