What was found
WING CENTER SECTION BREAK PANEL IS CRACKED AT FASTENER; BS 540; LBL 1; WL 207<[01] VERIFIED APPLICABILITY OF SRM 51-10-02-0G-0; NO DAMAGE LIMITS GIVEN IN SRM PART IS REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02-0G-0 PARA 9. REMOVED WING CENTER SECTION CRACK DAMAGED BREAK PANEL AT BS 540 LBL 1 TO LBL 24 IAW SRM 51-10-02-0G-0 REMOVED FLOOR PANEL 231UF FOR ACCESS IAW AMM 53-21-00-000-801;[02] PARTIAL STEP 1;[03] REMOVED AND REPLACED WING CENTER SECTION BREAK PANEL; BS 540; LBL 1 - LBL 25; WL 207 IAW SRM 51-40-02-0G-0 AND DWG 143A0060;[04] VERIFIED CORRECTIVE ACTIONS 1 & 3 COMPLETE;[05] VERIFIED MEASUREMENTS TABLE<BR>VERIFIED CARD COMPLETE.