As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION ON FORWARD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT STA 500A+2; +6; +10; +14; +18; 500B+2; +6; +18; RBL 24; WL 158.<[01] REPLACED ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT BETWEEN BS 500A - BS500D RBL.24 WL 156.5 IAW SRM 51-10-02; PARAG.9.C. DWG# 143A7500 REV: A;[02] VERIFIED CORRECTIVE ACTION ITEMS; CARD COMPLETE; EXCEPT MEASUREMENT FIELD ITEM 14 PART NUMBER INCOMPLETE BY AMT.;[03] CARD COMPLETE.