As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT ANGLE AT STA 460+18; 480+6; +10; 500A+14; 500B+17; 500C+13; LBL 24; WL 156.<[01] VERIFIED APPLICABILITY SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE.;[02] SEE STEP 3 FOR APPLICABILITY FOR ALLOWABLE DAMAGE;[03] VERIFIED CORRECTIVE ACTION 1.;[04] REMOVED AND REPLACED ON FCB FLOOR TO SIDEWALL SUPPORT;AT BS396 TO BS500D;LBL 24;WL156;IAW SRM 51-40-02 AND DWG#143A7500 REV A.;[05] TASK COMPLETE;[06] VERIFIED MEASUREMENT TABLE.<BR>TASK COMPLETE