What was found
FED CUTOUT SURROUND STRUCTURE - CRACK ON UPPER CHORD FRAME ASSY BS 312 STR-5L<[01] REQUEST NDI TO VERIFY CRACK AND IF CRACKED MARK ENDS OF CRACK BS 312 STR 5L UPPER RADIUS OF FRAME;[02] ACCOMPLISHED HFEC SURFACE SCAN IAW 737 NDTM PART 6 CHAPTER 51-00-00 PROCEDURE 23. CRACK CONFIRMED; MEASURED AT L: 0.2' MARKED.<BR><BR>EQUIPMENT USED: NORTEC 600 ID: ATS1465 CAL DUE: 09/2023;[03] UPDATED MEASUREMENT TABLE;[04] REPAIRED CRACK BS 312 STR 5L ON M-22-153-01244; TTG8Q00N56CS;[05] VERIFIED COMPLETION OF CORRECTIVE ACTIONS 4 AND MEASUREMENT TABLE.