What was found
CRACK ANGLE FLOOR STRUCTURE LOCATED ON BS 685 PLUS 6 INCHES AT RBL 24.75 AT PASSENGER CABIN 2023-568702<[01] REPLACED ANGLE FLOOR STRUCTURE LOCATED ON BS 685 PLUS 6 INCHES AT RBL 24.75 AT PASSENGER CABIN IAW B737-700 SRM 51-10-02; SRM 51-40-02 AND DWG 273A9112 SHEET: 30 AND BAC 1490-2782 SEE INDIVIDUAL SIGN OFF BELOW;[02] REPLACED ANGLE FLOOR STRUCTURE LOCATED ON BS 685 PLUS 6 INCHES AT RBL 24.75 AT PASSENGER CABIN IAW B737-700 SRM 51-10-02; SRM 51-40-02 AND DWG 273A9112 SHEET: 30 AND BAC 1490-2782 SEE INDIVIDUAL SIGN OFF BELOW<BR><BR>ITEM RII