What was found
IN THE FWD CARGO BAY; THE FLOOR SUPPORT ANGLE AT STATION 500I FROM LBL 24 TO RBL 24 HAS NUMEROUS AREAS OF CORROSION.<[01] BLENDED AREAS OF CORROSION ON FWD CARGO BAY; THE FLOOR SUPPORT ANGLE AT STATION 500I FROM LBL 24 TO RBL 24; BLENDS ARE OUT OF LIMITS ALL IAW SRM 53-00-53-1A-2.;[02] BLENDED AREAS OF CORROSION ON FWD CARGO BAY; THE FLOOR SUPPORT ANGLE AT STATION 500I FROM LBL 24 TO RBL 24; BLENDS ARE OUT OF LIMITS ALL IAW SRM 53-00-53-1A-2.;[03] REJECT: STEP #1 INDICATES WORKED PERFORMED BUT IS MISSING CERTIFYING SIGNATURE AND REFERENCE LISTED FOR THE WORK ACCOMPLISHED AS REQUIRED PER MPM 52.02.01.01 AND 51.03.01. SEE FAULT TTG8Q00NMDV0 FOR REJECTION FOUND FAULT.;[04] REMOVED AND INSTALLED NEW FWD CARGO FLOOR SUPPORT ANGLE AT STATION 500I FROM LBL 24 TO RBL 24. PER SRM 51-10-02 AND 51-40-02.