What was found
CRACK ON SUPPORT ANGLE FLOOR STRUCTURE LOCATED BTW BS 380 TO BS 400 LBL 14 AT PASSENGER CABIN 2023-550045<[01] TOOLS USED: TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 142811020; DUE DATE: 25-JAN-24; TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 142811019; DUE DATE: 25-JAN-24.;[02] REPLACED SUPPORT ANGLE FLOOR STRUCTURE LOCATED BTW BS 380 TO BS 400 LBL 14 AT PASSENGER CABIN IAW B737-800 SRM 51-40-02 AND DWG 143A5400 SEET 140 REV - SEE INDIVIDUAL SIGN OFF BELOW;[03] STEP 2 CORRECTED <BR><BR>REPLACED SUPPORT ANGLE FLOOR STRUCTURE LOCATED BTW BS 380 TO BS 400 LBL 14 AT PASSENGER CABIN IAW B737-800 SRM 51-40-02 AND DWG 143A5400 SHEET 140 REV - SEE INDIVIDUAL SIGN OFF BELOW;[04] REPLACED SUPPORT ANGLE FLOOR STRUCTURE LOCATED BTW BS 380 TO BS 400 LBL 14 AT PASSENGER CABIN IAW B737-800 SRM 51-40-02 AND DWG 143A5400 SHEET 140 REV - SEE INDIVIDUAL SIGN OFF BELOW CERTIFIED RII