What was found
CRACK ANGLE FLOOR STRUCTURE BS 695 AND LBL 24.75 LOWER POSITION AT PASSENGER CABIN 2023-569460<[01] TOOLS USED: TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 142811020; DUE DATE: 25-JAN-24; TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 112820025; DUE DATE: 01-FEB-24.;[02] REPLACED ANGLE FLOOR STRUCTURE LOC. BS 695 AND LBL 24.75 LOWER POSITION AT PASSENGER CABIN IAW B737-700 SRM 51-10-02 ITEM 9 AND DWG 111A600 SHEET 175 REV. -;[03] CORRECTED STEP 1<BR>REPLACED ANGLE FLOOR STRUCTURE LOC. BS 695 AND LBL 24.75 LOWER POSITION AT PASSENGER CABIN IAW B737-700 SRM 51-10-02 ITEM 9 AND DWG 111A600 SHEET 175 REV. - SEE INDIVIDUAL SIGN OFF BELOW;[04] CORRECTED STEP 2 AND 3<BR>REPLACED ANGLE FLOOR STRUCTURE LOC. BS 695 AND LBL 24.75 LOWER POSITION AT PASSENGER CABIN IAW B737-700 SRM 51-10-02 ITEM 9 AND DWG 111A600 SHEET 175 REV. - SEE INDIVIDUAL SIGN OFF BELOW;[05] CERTIFIED STEP 4 COMPLETED <BR>RII