What was found
WHILE ACCOMPLISHING A HOLE PROBE INSPECTION PER E/A TTG8Q00NJTYG ( STEP 15) FOUND EXISTING OPEN HOLE HAS A CRACK INDICATION. 6' AFT OF STA 1040 ON STRINGER 23R. 5TH OPEN HOLE FROM FWD END. SEE PICTURE<[01] WHILE ACCOMPLISHING A HOLE PROBE INSPECTION PER E/A TTG8Q00NJTYG ( STEP 15) FOUND EXISTING OPEN HOLE HAS A CRACK INDICATION. 6' AFT OF STA 1040 ON STRINGER 23R. 5TH OPEN HOLE FROM FWD END. (CRACK INDICATION IS ON THE OUTER SKIN HOLE);[02] REPAIR ACCOMPLISHED PER EA 23-153-02853-WIP3.;[03] 2. JOSHUA PHIPPS (TECHNICIAN); 01-OCT-2023 09:29 UTC<BR>REPAIR ACCOMPLISHED PER EA 23-153-02853-WIP3. INSPECTED.