What was found
FWD CARGO COMP.PANEL 120DF AFT EDGE CORRODED AROUND FASTNER HOLES<[01] UPON FURTHER INVESTIGATION FOUND CORROSION TO EXCEED THE ALLOWABLE LIMITS WITH THE MAX ALLOWED LENGTH BEING 3 INCHES FOUND TO BE OUT OF LIMITS I.A.W SRM 53-00-53-1A-1;[02] VERIFIED MATERIAL WITH P/N: 2024-T3-071 AND AAR TAG: A133191 I.A.W SRM 53-30-53-0I-1;[03] VERIFIED STEP 2 COMPLETE;[04] FABRICATED PANEL 120DF I.A.W AMM 50-10-04-400-801.;[05] VERIFIED STEP 4 COMPLETE<BR><BR>OK TO TREAT & PRIME;[06] APPLIED TREAT AND PRIMER ON NEW PANEL 120DF I.A.W AMM 51-21-41-701 AND AMM 51-21-72-701;[07] VERIFIED ITEM 6<BR>AUDIT C/W