What was found
MID AFT EMERGENCY EXIT LIGHT BATTERY PACK (M1670 STA 727C+13 WL 212 LBL 68) DOES NOT CHARGE<[01] REMOVED ACCESS PANEL AT STA. 727C+13 WL 212 RBL 68 IAW AMM 33-51-06-960-802 STEP 4D.(3).;[02] CORRECTED STEP 1 FROM STA. RBL TO LBL.<BR><BR>REMOVED ACCESS PANEL AT STA. 727C+13 WL 212 LBL 68 IAW AMM 33-51-06-960-802 STEP 4D.(3).;[03] REMOVED AND INSTALLED NEW EMERGENCY EXIT LIGHT BATTERY PACK AT M1670 IAW AMM 33-51-06-960-802 STEP 4D.(4)(5). A-TAG# WN36673.;[04] ACCOMPLISHED EMERGENCY EXIT LIGHT TEST IAW AMM 33-51-06-960-802 STEP 4D.(6). OPS CHECK GOOD.;[05] VERIFIED STEP 4<BR>OK TO INSTALL PANEL;[06] VERIFIED STEP 3 AND 4<BR>OK TO INSTALL PANEL;[07] RE-INSTALLED PANEL AT M1670 IAW AMM 33-51-06-960-802 STEP 4E.;[08] VERIFIED STEP 7<BR>AUDIT CW