What was found
MID EMERGENCY EXIT LIGHT BATTERY PACK (M1695 STA 565 WL 213 RBL 68) DOES NOT CHARGE<[01] REMOVED PANEL AT STA 565 WL 213 RBL 68 IAW AMM 33-51-06-960-802 STEP 4.A THRU 4.D(3).;[02] REMOVED BATTERY PACK AT STA 565 WL 213 RBL 68 IAW AMM 33-51-06-960-802 STEP 4.D(4).;[03] CORRECTION STEP 2:<BR>REMOVED BATTERY PACK M1695 AT STA 565 WL 213 RBL 68 IAW AMM 33-51-06-960-802 STEP 4.D(4).;[04] REMOVED BATTERY PACK M1695 AT STA 565 WL 213 RBL 68 IAW AMM 33-51-06-960-802 STEP 4.D(5).;[05] CORRECTION STEP 4:<BR>INSTALLED BATTERY PACK M1695 AT STA 565 WL 213 RBL 68 IAW AMM 33-51-06-960-802 STEP 4.D(5).;[06] ATAG STEP 5: WN36674;[07] ACCOMPLISHED EMERGENCY EXIT LIGHT TEST IAW AMM 33-51-06-960-802 STEP 4D.(6). OPS CHECK GOOD.;[08] VERIFIED STEP 5;6 & 7<BR>OK TO INSTALL PANEL;[09] RE-INSTALLED PANEL AT M1695 IAW AMM 33-51-06-960-802 STEP 4E.;[10] VERIFIED STEP 9<BR>AUDIT CW