What was found
FWD/MID EMERGENCY EXIT LIGHT BATTERY PACK (M2335 STA 500C+7 WL 213 LBL 67) DOES NOT CHARGE<[01] REMOVED PANEL AT STA 500C+7 WL 213 RBL 67 IAW AMM 33-51-06-960-802 STEP 4.A THRU 4.D(3).;[02] REMOVED BATTERY PACK M2335 AT STA 500+7 WL 213 RBL 67 IAW AMM 33-51-06-960-802 STEP 4.D(4).;[03] INSTALLED BATTERY PACK M2335 AT STA 500+7 WL 213 RBL 67 IAW AMM 33-51-06-960-802 STEP 4.D(5).;[04] ACCOMPLISHED EMERGENCY LIGHTS OPS CHECK IAW AMM 33-51-06-960-802 STEP 4.D(6). OPS CHECK GOOD.;[05] VERIFIED STEP 3&4<BR>OK TO INSTALL PANEL;[06] INSTALLED PANEL AT STA 500C+7 WL 213 RBL 67 IAW AMM 33-51-06-960-802 STEP 4.E.;[07] VERIFIED STEP 6<BR>AUDIT CW