What was found
FWD/MID EMERGENCY EXIT LIGHT BATTERY PACK (M1676 STA 500C+7 WL 213 RBL 67) DOES NOT CHARGE<[01] REMOVED ACCESS PANEL AT STA. 500C+7 WL 213 RBL 67 IAW AMM 33-51-06-960-802 STEP 4D.(3).;[02] REMOVED AND REPLACED BATTERY PACK M1676 AT STA 500C+7 WL 213 RBL 67 IAW AMM 33-51-06-960-802 STEP 4.D(4) AND (5).;[03] ACCOMPLISHED EMERGENCY LIGHTS OPS CHECK IAW AMM 33-51-06-960-802 STEP 4.D(6). OPS CHECK GOOD.;[04] VERIFIED STEP 2&3<BR>OK TO INSTALL PANEL;[05] INSTALLED ACCESS PANEL AT STA. 500C+7 WL 213 RBL 67 IAW AMM 33-51-06-960-802 STEP 4.E.;[06] VERIFIED STEP 5<BR>AUDIT CW