What was found
CRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS 277 TO BS 294.5 AND BL 0 FWD GALLEY AND LAV 2023-584561<[01] REPLACED WEB INTERCOSTAL AND FASTENERS LOCATED ON FLOOR STRUCTURE BETWEEN BS 277 TO BS 294.5 AND BL 0 FWD GALLEY AND LAV IAW B737-700 SRM 51-10-02 ITEM 9 AND DWG: 141A5400 SHEET: 20 REV.: ?<BR>SEE INDIVIDUAL SIGN-OFF BELOW;[02] TASK CARD COMPLETED <BR>REPLACED WEB INTERCOSTAL AND FASTENERS LOCATED ON FLOOR STRUCTURE BETWEEN BS 277 TO BS 294.5 AND BL 0 FWD GALLEY AND LAV IAW B737-700 SRM 51-10-02 ITEM 9 AND DWG: 141A5400 SHEET: 20 REV.: ? <BR>SEE INDIVIDUAL SIGN-OFF BELOW<BR>RII