What was found
CRACK ON SUPPORT ANGLE LOCATED FLOOR STRUCTURE FWD FACE BS 695 RBL 1 WL 208.1 AT CENTER SECTION 2023-577693<[01] TOOLS USED: TEMPERATURE CONTROLLER: P/N: P3015GOES00000; S/N: 142811020; DUE DATE: 25-JAN-24; TEMPERATURE CONTROLLER: P/N: P3015GOES00000; S/N: 142811019; DUE DATE: 25-JAN-24.;[02] REPLACED SUPPORT ANGLE LOCATED FLOOR STRUCTURE FWD FACE BS 695 RBL 1 WL 208.1 AT CENTER SECTION IAW B737-700 SRM 51-40-02 AND DRAWING # 273A9111 REV -. SEE INDIVIDUAL SIGN OFF BELOW.;[03] CERTIFIED STEP 2 COMPLETED <BR>RII