What was found
CRACK FLOOR BEAM LOCATED STA 294.5 AND RBL 54 AT FWD GALLEY AREA 2023-577850<[01] TOOL USED EDDY CURRENT P/N: NORTEC 600D; S/N: 210138203; DUE DATE: 09-JUN-24.;[02] TOOL USED: RADIOMETER PHOTOMETER P/N: XRP-3000; S/N: 1753759; CAL DUE DATE: 14-OCT-23;[03] TOOL USED: TEMPERATURE CONTROLLER P/N P3015GOES00000 S/N 142811019 DUE DATE: 25-JAN-24. TEMPERATURE CONTROLLER P/N P3015GOES00000 S/N 142811020 DUE DATE: 25-JAN-24.;[04] TOOL USED: RADIOMETER KIT; P/N: XRP-3000; S/N: 1859843; DUE DATE: 05-DEC-23.;[05] PERFORMED PERMANENT REPAIR ON FLOOR BEAM STA 249.5 BTW RBL20 TO RBL60 AT FWD GALLEY AREA I.A.W. B737-700 SRM 53-10-51-2R-16<BR><BR>SEE INDIVIDUAL SIGN-OFF BELOW;[06] PERFORMED PERMANENT REPAIR ON FLOOR BEAM STA 249.5 BTW RBL20 TO RBL60 AT FWD GALLEY AREA I.A.W. B737-700 SRM 53-10-51-2R-16; RII; SEE INDIVIDUAL SIGN-OFF BELOW