What was found
CORROSION ON AFT CARGO COMPARTMENT FLOOR TO SIDEWALL SUPPORT ANGLE AT STATIONS: 767; 767+6; 767+10; WL 156; LBL 22.<[01] THIS CARD WILL BE ACCOMPLISHED ON CUSTOMER CARD NBR: TTG8Q00NPGFW;[02] VERIFIED APPLICABILITY PER SRM 53-60-53-0I-1 AND ALLOWABLE DAMAGE SRM 53-00-53-1A-2.<BR>REMOVED CORROSION ON AFT CARGO COMPARTMENT FLOOR TO SIDEWALL SUPPORT ANGLE REWORKED AREAS FOUND MULTIPLES AREAS WITH MORE 50% OF LOSS MATERIAL BS 767+10 L=1.3' ; W=1.5' ; D= 0.032'. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2 STEP A(2)(A) FIG 103<BR>TOOL USED:ATS2472<BR>DUE:12/31/23;[03] VERIFIED STEPS 1 AND 2; MEASUREMENT TABLE; CARD COMPLETE.