What was found
INTERCOSTAL CRACKED; BS294-277; BL0; WL208<[01] UPDATED STEP #1;[02] INTERCOSTAL IS PRIMARY STRUCTURE. LOCATED AND DRILLED IAW DWG 141A5400; SRM 51-40-05-0G-0;[03] CERTIFY EDIT TO ACTION #1;[04] COMPLETED INSTALLATION OF INTERCOSTAL IAW DWG 141A5400; SRM 51-40-02=0G-0.;[05] FOUND NO LIMITATIONS IN SRM FOR CRACKED INTERCOSTAL. REMOVED AND REPLACED INTERCOSTAL IAW SRM 51-40-05-0G-0; SRM 51-40-02-0G-0; DWG 141A5400;[06] INSTALLED INTERCOSTAL IAW SRM 51-40-05-0G-0; SRM 51-40-02-0G-0; DWG 141A5400;[07] CERTIFY CORRECTIVE ACTION;[08] VERIFIED CORRECTIVE ACTION 4;5;6