What was found
CORROSION; FLOOR TO SIDEWALL SUPPORT; BS 747; +4 +6; +8; RBL22; WL156<[01] REMOVED CORROSION FROM AFT CARGO BEY FLOOR TO SIDE WALL SUPPORT ANGLE IN AREA OF (1'X2'X0.020'DEEP) AT BS 747+4; (1.5'X2'X0.015'DEEP) AT BS 747+6; (2.5'X1.2'X0.010'DEEP) AT BS 7247+8; RBL 22; WL 156; OUT OF 0.040' ORIGINAL MATERIAL THICKNESS FOUND TO BE OUT OF LIMIT IAW SRM 53-00-53-1A-2 DET.4A; FIG 103-D<BR><BR>THIS FAULT WILL BE ACCOMPLISHED ON CARD # TTG8Q00NY164.;[02] VERIFIED CORRECTIVE ACTION AND MEASUREMENTS TABLE. REPAIR WILL BE ACCOMPLISHED ON CARD # TTG8Q00NY164. <BR>CARD COMPLETE.