What was found
CORROSION BETWEEN STA 291.5 TO STA 344; LBL 64 AND WL 208.1<[01] REMOVED UPPER CORD ANGLE BETWEEN STA291.5 TO STA 344;LBL64 WL 208.1;LOCATED AND DRILLED REF:SRM 51-40-02-OG-0;[02] REMOVED UPPER CHORD ANGLE BETWEEN STA 291.5 TO STA 344; LBL 64 AND WL 208.1 AS PER SRM-51-40-02-0G-0. LOCATED AND DRILLED NEW ANGLE PART #141A8112U20 AT STA 291.5 TO STA 344; LBL 64 AND WL 208.1 REF SRM 51-40-02-0G-0. INSTALLED NEW ANGLE AT STA 291.5 TO STA 344; LBL 64 AND WL 208.1 REF: SRM 51-40-02-0G-0 DWG#142A8410. MIX PRC BMS 5-95 ON SEPT 29-2023 18:00; SQUEEZE OUT TIME SEPT 29-2023 20:00.;[03] VERIFIED STEP:2 INSTALLED NEW ANGLE AT STA 291.5 TO STA 344; LBL 64 AND WL 208.1