What was found
CRACK STRINGER 25R LOCATED BS540 AT FWD CARGO COMPARTMENT 2023-637779<[01] TOOL USED: ULTRASONIC THICKNESS GAUGE; PN: 45MG; SN: 221861811; DUE DATE: 08-NOV-23;[02] EDDY CURRENT EQUIPMENT USED P/N: NORTEC 600D; S/N: 220273012 AND DUE DATE: 17-DEC-23.;[03] TOOL USED: TEMPERATURE CONTROLLER P/N P3015GOES00000 S/N 142811020 DUE DATE 25 JAN 24; P/N P3015GOES00000 S/N 142811019 DUE DATE 25 JAN 24.;[04] PERFORMED PERMANENT REPAIR ON STRINGER 25R LOCATED BETWEEN BS500C + 10? TO BS540 AT FWD CARGO COMPARTMENT IAW. B737-700 SRM 53-00-03-2R-1.<BR>SEE INDIVIDUAL SIGN OFF BELOW;[05] PERFORMED PERMANENT REPAIR ON STRINGER 25R LOCATED BETWEEN BS500C + 10? TO BS540 AT FWD CARGO COMPARTMENT IAW. B737-700 SRM 53-00-03-2R-1.<BR>RII<BR>SEE INDIVIDUAL SIGN OFF BELOW