What was found
CORROSION; CABIN PASSENGER AFT WET AREA R2 DOOR LOWER INNER CHORD BETWEEN STA 951 AND STA 992. RBL 50; WL 208.1.<[01] REMOVED AND REPLACED R2 DOOR LOWER INNER CHORD AS PER SRM 51-40-02-0G-0 AND DWG 147A8501.;[02] ADDING TO STEP 1: REMOVED CORROSION AT CABIN PASSENGER AFT WET AREA R2 DOOR LOWER INNER CHORD BETWEEN STA 951 AND STA 992. RBL 50; WL 208.1. AS PER SRM 51-10-02-0G-0; ORIGINAL THICKNESS 0.080'. MATERIAL LOST 0.012'; MATERIAL REMAINING 0.068'. FOUND OUT OF LIMITS AS PER SRM 53-70-15-1A-1; REMOVED AND REPLACED R2 DOOR LOWER INNER CHORD AS PER SRM 51-40-02-0G-0 AND DWG 147A8501.;[03] VERIFIED R2 DOOR LOWER INNER CHORD REPLACEMENT.