What was found
CORROSION FWD CARGO BAY R/H FLOOR TO SIDEWALL SUPPORT PLATE MULTIPLE AREAS AROUND NUT PLATE HOLES BS500A TO BS500I RBL22 WL156<[01] VERIFIED STEP 1 COMPLETE; STEP 2;3 IN PARTIAL.;[02] VERIFIED STEP 4 COMPLETE.;[03] EVALUATED CORROSION ON FCB RH FLOOR TO SIDEWALL SUPPORT; FOUND TO BE OUT OF LIMITS; IAW 53-00-53-1A-2. REMOVED DAMAGED FCB RH FLOOR TO SIDEWALL SUPPORT; RECEIVED NEW FLOOR TO SIDEWALL SUPPORT; LOCATED AND DRILLED; IAW SRM 51-40-05; AND INSTALLED FCB RH FLOOR TO SIDEWALL SUPPORT. BS500A TO 500I; RBL22 IAW SRM 51-40-02-0G-0. DWG 143A7500.;[04] FINAL INSPECTION. JOB COMPLETE.