What was found
RIGHT GEAR DELAYED COMING DOWN; IT TOOK 45 SECONDS FOR A GREEN INDICATION DOWN AND LOCKED<[01] PERFORM PSEU BITE FOUND FC 32-64001; OK TO CONTINUE PER MEL 32-16-01 SP1;[02] PER FIM REMOVED AND REPLACED RIGHT MLG RETRACT ACTUATOR IAW AMM 32-32-11-400-801 STEPS A THROUGH H. STEPS I THROUGH K NEED TO BE COMPLETED;[03] ACCOMPLISHED INSTALLATION OF RH MLG ACTUATOR IAW AMM 32-32-11-400-801 STEPS A THROUGH H.;[04] PERFORMED STEPS I THROUGH K IAW MM 32-32-11-400-801;[05] PERFORMED STEPS I THROUGH K IAW MM 32-32-11-400-801;[06] C/W