What was found
CRACK ANGLE FLOOR STRUCTURE LOCATED BS695 AND BL 0 CENTER SECTION 2023-659069<[01] TOOL USED: TEMPERATURE CONTROLLER: P/N: P3015GOES00000; S/N: 142811020; DUE DATE: 25-JAN-24; TEMPERATURE CONTROLLER: P/N: P3015GOES00000; S/N: 142811019; DUE DATE: 25-JAN-24.;[02] REPLACED SUPPORT ANGLE LOCATED ON FLOOR STRUCTURE BS695 AND BL 0 CENTER SECTION I.A.W B737-700 SRM 51-40-02-0G-0 AND DWG# 273A9110; SHEET 6; REV.A. SEE INDIVIDUAL SIGN OFF BELOW.;[03] CORRECTIVE ACTION STEP 2 CERTIFIED