What was found
LEFT HORIZONTAL STAB RIB # 6 AFT STIFFENER WAS FOUND CRACKED AFTER RIB REMOVAL<[01] REMOVED AND INSTALLED NEW STIFFENER AT LEFT HORIZONTAL STAB RIB # 6 REF 51-40-02-0G-0; DWG 182A1505 AND EA23-155-03219 (WIP 1).;[02] RII; VERIFIED STEP # 1;[03] REMOVED AND INSTALLED NEW STIFFENER AT LEFT HORIZONTAL STAB RIB # 6 REF 51-40-02-0G-0; DWG 182A1505 AND EA23-155-03219 (WIP 1).;[04] RII; VERIFIED REPLACEMENT OF AFT STIFFENER AT HORIZONTAL STAB. RIB # 6;[05] VERIFIED WORKMANSHIP WAS DONE AS PER APPROVED REFERENCES.;[06] EA EA-COMPONENT (EA ATTACHED TO A FAULT FOR A TRACKED COMPONENT) SELECTED AS REPAIR REFERENCE. SEE TASK CARD # TTG8Q00PMEXV;[07] VERIFIED STEP 6;[08] ADDED DE LABOR ROW ONLY TO CLEAR 'IN WORK' STATUS OF COMPLETED FAULT.