What was found
FLOOR SUPPORT INTERCOSTAL CRACKED AT BL 0; WL 208; BS 284 AND BS 291<[01] REMOVED AND REPLACED FLOOR SUPPORT INTERCOSTAL AT BL 0; WL 208 BS 284 AND BS 291 IAW SRM 51-40-05 AND DWG 141A5400;[02] VERIFIED.<BR>VERIFIED MEASUREMENTS.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR SUPPORT INTERCOSTAL CRACKED AT BL 0; WL 208; BS 284 AND BS 291<[01] REMOVED AND REPLACED FLOOR SUPPORT INTERCOSTAL AT BL 0; WL 208 BS 284 AND BS 291 IAW SRM 51-40-05 AND DWG 141A5400;[02] VERIFIED.<BR>VERIFIED MEASUREMENTS.