What was found
FLOOR SUPPORT INTERCOSTAL CRACKED AT BS 321; LBL 46; WL 208<[01] REMOVED AND REPLACED FLOOR SUPPORT INTERCOSTAL<BR>BS 321 LBL 46 WL 208<BR>IAW SRM 51-40-05 AND DWG 141A5400;[02] VERIFIED CORRECTIVE ACTION COMPLETE; WITH MEASUREMENTS.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR SUPPORT INTERCOSTAL CRACKED AT BS 321; LBL 46; WL 208<[01] REMOVED AND REPLACED FLOOR SUPPORT INTERCOSTAL<BR>BS 321 LBL 46 WL 208<BR>IAW SRM 51-40-05 AND DWG 141A5400;[02] VERIFIED CORRECTIVE ACTION COMPLETE; WITH MEASUREMENTS.