What was found
FLOOR TO SIDEWALL SUPPORT IS CORRODED AT BS 480+14 AND 500+10; LBL 25; WL 156<[01] REMOVED AND NEW INSTALLED FLOOR TO SIDEWALL SUPPORT AT BS 480+14 TO BS 500D LBL 25 IAW SRM 51-40-02 AND DWG 143A7501; DWG 145A7500;[02] VERIFIED.<BR>VERIFIED MEASUREMENTS.