What was found
SURFACE CORROSION ON R/H TRANSITION ANGLE STA. 727J - 747 RBL 21 (MARKED)<[01] REMOVED CORROSION ON RH TRANSITION ANGLE STA 727J- 747. REMAINING THICKNESS IS 0.035. FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2;[02] C/W INSP. CORROSION ON RH TRANSITION ANGLE STA 747J - 747. REMAINING THICKNESS IS 0.035. FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2;[03] LINE 2 ENTERED IN ERROR.;[04] C/W INSP. CORROSION ON RH TRANSITION ANGLE STA 727J- 747. REMAINING THICKNESS IS 0.035. FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2;[05] ALL WORK ACCOMPLISHED ON CARD TTG8Q00P6BMF.;[06] C/W INSP. ALL WORK ACCOMPLISHED ON CARD TTG8Q00P6BMF.