What was found
CORROSION ON FCB AFT BHD LOWER SUPPORT ANGLE AT BS 500H+21 WL156; AT LBL 3; LBL 9; LBL 13.5; LBL 17.5; LBL 23.5; RBL 2.5; RBL 9; RBL 13; RBL 18; AND RBL 23<[01] REMOVED CORROSION ON FCB AFT BHD LOWER SUPPORT ANGLE <BR>BS 500H RBL 24 TO LBL 24 WL 156 FOUND OUT OF LIMITS<BR>IAW SRM 53-00-53-1A-2 ALLOWABLE DAMAGE 2<BR><BR>REMOVED AND REPLACED FCB AFT BHD LOWER SUPPORT ANGLE<BR>BS 500H RBL 24 LBL 24 IAW SRM 51-40-05;SRM 51-40-02 AND <BR>DWG 143A9481;[02] VERIFIED JOB COMPLETE<BR><BR>VERIFIED MEASUREMENT TABLE