What was found
CORROSION ON FLOOR SUPPORT AT SEVERAL FASTENER HOLES BS947+3 LBL15 -LBL48<[01] REMOVED FLOOR SUPPORT BS 947 +3 LBL 16 TO LBL 24 IAW SRM 51-40-02.;[02] REMOVED INTERCOSTAL BS947 TO BS967 LBL 24 IAW SRM 51-40-02.;[03] REMOVED FLOOR SUPPORT ANGLE BS947 +3 LBL24 TO LBL48 IAW SRM 51-40-02.;[04] LOCATED/DRILLED REPLACEMENT INTERCOSTAL BS947 TO BS967 LBL 24 AND INSTALLED IAW SRM 51-40-02.;[05] LOCATED/DRILLED FLOOR SUPPORT ANGLE BS947 +3 LBL24 TO LBL48 AND INSTALLED IAW SRM 51-40-02.;[06] CORRECTIVE ACTION 5 SHOULD STATE LOCATED/DRILLED REPLACEMENT FLOOR SUPPORT ANGLE BS947 +3 LBL24 TO LBL48 AND INSTALLED IAW SRM 51-40-02.;[07] C/W INSPECTION.;[08] LOCATED AND DRILLED FLOOR SUPPORT P/N 147A5675-1 PER SRM 51-40-05. INSTALLED FLOOR SUPPORT AT STA 947 + 3?; LBL 16-LBL 24 PER SRM 51-40-02.;[09] INSPECTED AS REQUIRED. CORRECTIVE ACTION #8