What was found
AFT CARGO R/H TRANSITION WEB AT STA. 847-867 HAS LIGHT SURFACE CORROSION.<[01] BLENDED CORROSION ON R/H TRANSITION ANGLE FROM STA. 847 TO STA. 867 AT RBL 21? PER SRM 51-10-02. REMOVED .012? OF MATERIAL. REMAINING THICKNESS IS .038?. DAMAGE REMOVAL IS OUT OF LIMITS PER SRM 53-00-53-1A-2.;[02] REMOVED TRANSITION ANGLE FROM STA. 847 TO STA. 867 AT RBL 21? PER SRM 51-40-02.;[03] VERIFIED C/A 1 AND 2;[04] LOCATED AND DRILLED NEW SHIELD ASSY IAW SRM 51-40-02.;[05] RII: VERIFIED CORRECTIVE ACTION #4;[06] OK TO INSTALL;[07] INSTALLED NEW SHIELD ASSY IAW SRM 51-40-02.;[08] RII: VERIFIED CORRECTIVE ACTION #7