What was found
TOP SURFACE OF FLOOR BEAM @STA 947; LBL 52 HAS CORROSION OUTBOARD SIDE OF LAV MOUNT TOP SURFACE OF FLOOR BEAM @STA 947 LBL 52 HAS CORROSION OUTBOARD SIDE OF LAV MOUNT<[01] REMOVED CORROSION PER SRM 51-10-02. FOUND AREA OUT OF LIMITS PER SRM 53-70-51-1A-1.;[02] ACCOMPLISHED HFEC SURFACE AND HOLE PROBE INSP. OF TOP FLANGE OF 947 FLOOR BEAM LBL 52' PER NDT PART 6 51-00-00 PROC. 23 AND 51-00-00 PROC. 16 NO DEFECTS NOTED;[03] REMOVED ADDITIONAL.002 MATERIAL PER SRM 51-10-02 AND SRM 53-70-51-2R-8. FLAP PEENED DAMAGED AREA PER SOPM 20-10-03.;[04] FABRICATED SHIM PER SRM 53-70-51-2R-8.;[05] REMOVED ADDITIONAL.002 MATERIAL PER SRM 51-10-02 AND SRM 53-70-51-2R-8. FLAP PEENED DAMAGED AREA PER SOPM 20-10-03. FABRICATED SHIM PER SRM 53-70-51-2R-8.;[06] OK TO INSTALL. RII INSPECTION C/W.;[07] RII INSPECTION C/W.;[08] C/W INSPECTION.;[09] REPAIRED 947 FLOORBEAM LBL 52 PER SRM 53-70-51-2R-8;[10] C/W INSPECTION.