What was found
FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT IS CORRODED AT BS 500D+8 - 500A; LBL 22; WL 155<[01] UPDATED STEP 7.;[02] UPDATED STEP 8;[03] UPDATED STEP 9;[04] REMOVED DAMAGED FLOOR TO SIDEWALL SUPPORT BS 480+8' TO BS 500I; LBL 22;WL 155 INSTALLED NEW SIDEWALL SUPPORT AT FCB BETWEEN BS 480+8' TO BS 500I; LBL 22;WL 155 IAW SRM 51-40-02 ;SRM 53-00-53-2R-5; DWG:143A7500 AND EA# M-22-153-01550. INSTALLED SPLICE REPAIR ON SIDEWALL SUPPORT BETWEEN BS 500D+4' TO BS 500D+15';[05] VERIFIED CORRECTIVE ACTION COMPLETE; WITH MEASUREMENTS.