What was found
CORROSION FLOOR STRUCTURE FLOOR BEAM LOCATED BS 986.5 LBL 38 AND WL 208.1 AT AFT GALLEY AREA 2023-694125<[01] TOOL USED : EDDY CURRENT EQUIPMENT P/N NORTEC500D S/N 00X12101V022237 DUE DATE: 26-JAN-24.;[06] CORRECTIVE STEP 5 PERFORMED REPAIR LOCATED ON FLOOR BEAM LOCATED BS 986.5 BETWEEN LBL35 TO LBL 47 AND WL 208.1 AT AFT GALLEY AREA IAW B737-700 SRM 53-70-51-2R-6 REPAIR 6 PARAGRAPH 4; ALTERNATIVE 4 FIGURE 205 SHEET 1 TO SHEET 3 AND ALL STEPS ARE DOCUMENTED ON FAULT TTG8Q00PK3S6 . SEE INDIVIDUAL SIGN OFF BELOW.<BR>AS RII