What was found
FLOOR BEAM CORRODED STA 947 AT RBL-50 DEEP PIT AT EDGE OF GALLEY FITTING<[01] REMOVED CORROSION PER SRM 51-10-02. THE REWORKED AREA IS OUT OF LIMIT PER SRM 53-70-51-1A-1 FIG 104 DETAIL N.;[15] INSTALLED ALL FASTENERS IN STA 947 SPLICE ANGLES PER SRM 53-70-51-2R-5.;[16] REPAIRED DAMAGED SECTION OF STA 947 FLOOR BEAM I.A.W SRM 53-70-51-2R-5. SEE CORRECTIVE ACTIONS AND WORKSTEPS FOR INDIVIDUAL WORK ACCOMPLISHED.;[17] INSP THE REPAIRED DAMAGED SECTION OF STA 947 FLOOR BEAM I.A.W SRM 53-70-51-2R-5. SEE CORRECTIVE ACTIONS AND WORKSTEPS FOR INDIVIDUAL WORK ACCOMPLISHED