What was found
C/R DURING AAI INSPECTION FOUND FWD CARGO COMPARTMENT; EXISTING FLOOR TO SIDEWALL SUPPORT REPAIR - SUPPORT SHIELD HAS ELONGATED FASTENER HOLE AND IMPROPER (2EA) FASTENERS INSTALLED BTW STA 490 - 500 FWD CARGO COMPARTMENT EXISTING FLOOR TO SIDEWALL SUPPORT REPAIR - SUPPORT SHIELD HAS ELONGATED FASTENER HOLE AND IMPROPER (2EA) FASTENERS INSTALLED BTW STA 490 - 500 STR 25R.<[01] REMOVED AND REPLACED SUPPORT SHIELD AND FABRICATED WEB AT FWD CARGO RBL 25 FLOOR TO SIDEWALL SUPPORT STRUCTURE. SPER SRM 51-40-02-G-0 AND DWG 143A0080;[02] REMOVED AND REPLACED SUPPORT SHIELD AND FABRICATED WEB AT FWD CARGO RBL 25; STA 490 TO 500 FLOOR TO SIDEWALL SUPPORT STRUCTURE. SPER SRM 51-40-02-G-0 AND DWG 143A0080;[03] VERIFIED CORRECTIVE ACTION STEPS 1 AND 2