What was found
FWD CARGO BAY AFT FLOOR TO SIDEWALL SUPPORT HAS CORROSION AT BS 500A+10 - 500B+8; RBL 25; WL 156<[01] REMOVED AND REPLACED FWD CARGO BAY FLOOR TO SIDE WALL SUPPORT ANGLE BS 500A TO BS500D RBL 25; WL 165 IAW SRM 51-40-02 AND DWG# 143A7500;[02] VERIFIED CORRECTIVE ACTION AND STEPS COMPLETE; VERIFIED MEASUREMENT TABLE.