What was found
CRACKED STUB FRAME AT THE FWD GALLEY DOORWAY; BS 294.5; RBL 54; WL 208.1; IB FLANGE MARKED.<[01] NDT HFEC SURFACE INSPECTED AREA IAW 737 NDTM PART 6 51-00-00 PROC 23. CRACK NOTED; .75' LONG; DIRECTION AND END OF CRACK MARKED. <BR>EQUIP USED: NORTEC 600 IS0000680 DUE 05/24;[02] REPAIRED THE STUB FRAME AT THE FWD GALLEY DOORWAY; BS 294.5; RBL 54; WL 208.1; IB FLANGE IAW SRM 53-10-15-2R-7 REPAIR 7;[03] VERIFIED COMPLETION OF CORRECTIVE ACTIONS 2 AND MEASUREMENT TABLE.