What was found
CORROSION SPOT AT R/W FRONT SPAR L/E FUEL QTY INDICATORS SUPPORT PANEL MKD DOT<[01] REMOVED REFUEL PANEL (P15) PER TASK 28-21-00-000-801; INSTALLED EWIS PROTECTION FOR MAINTENACE PER TASK 20-60-07-913-801;REMOVED AND REPLACED P15 INDICATOR FACEPLATE/BRACKET ASSY PER B737 SWPM 20-10-11 & AMM 28-41-61-000-801 & 28-41-61-400-801; WDM 28-44-11.REMOVED & REPLACED CENTER TANK REFUEL VALVE OPEN LIGHT ASSEMBLY (L284). REF. TO SWPM 20 84-20; TEST WILL BE COMPLETED ON STEP 7. REMOVED EWIS PROTECTION FOR MAINTENACE PER TASK 20-60-07-913-801 INSTALLED REFUELING PANEL P15 PER TASK 28-21-00-400-801PERFORMED REFUELING PANEL P15 INSTALLATION TEST; TEST PASSED; BONDING CHECK FOUND WITHIN LIMITS. PER B737 AMM 28-21-00-400-801.USED BONDING METER B/C 16813; DUE DATE 17-OCT-24.;[02] FINAL INSPECTION; VERIFIED STEP #1.