What was found
AFT PASSENGER COMPARTMENT FLOOR STRUCTURE HAS EVIDENCE OF CORROSION AT INTERCOASTAL STA 947 LBL 24<[01] REMOVED L ANGLE REMOVED CORROSION AT BS 927-947 LBL 24 FOUND OUT OF LIMIT IAW SRM 53-70-51-1A-1;[02] REJECT: FAULT HAS 4 ERRORS PRESENT:<BR><BR>1. CORRECTIVE ACTION #1 HAS INCORRECT REFERENCE NOTED FOR ALLOWABLE LIMITS WHICH SHOULD BE SRM 53-70-51-0I-2 FOR THIS AREA AS THIS COVERS THE SPECIFIC INTERCOSTAL LISTED IN FAULT DETAIL.<BR><BR>2. MEASUREMENT SECTION ITEM #3 IS ENTERED AS FAILURE TYPE NO WHEN THE FAILURE TYPE FOR THIS FAULT IS LISTED AS 03 CP AND THEREFORE SHOULD BE ANSWERED AS YES.<BR><BR>3. MEASUREMENT SECTION ITEM #23 HAS THE CORROSION LEVEL LISTED AS LEVEL 1; HOWEVER CORROSION FOUND AS OUT OF LIMITS SHOULD BE LISTED AS LEVEL 2. SEE MPM GLOSSARY UNDER 'CPCP LEVEL 2 CORROSION' FOR DEFINITIONS.<BR><BR>4. MEASUREMENT ITEM #22 IS LISTED AS NO; BUT SHOULD BE LISTED AS YES DUE TO FINDING OF OUT OF LIMITS NOTED IN CORRECTIVE ACTION #1 AND FAULT SHOULD HAVE PICTURE OF CORROSION ATTACHED. SEE MPM GLOSSARY UNDER 'CPCP LEVEL 2 CORROSION' FOR DEFINITIONS.;[03] REFERENCING REJECTION NOTED IN CORRECTIVE ACTION #2:<BR>INSPECTION CONFIRMS THAT ISSUE ITEMS #2; #3 AND #4 HAVE BEEN CORRECTED. ISSUE ITEM #1 WAS REJECTED IN ERROR AS THE REFERENCE USED IN CORRECTIVE ACTION #1 WAS CORRECT. REMOVED AND REPLACED L ANGLE BS 927-947 LBL 24 PER SRM 51-40-02;[08] C/W INSPECTION;[09] C/W INSPECTION