What was found
AFT CARGO R/H TRANSITION ANGLE HAS CORROSION RBL 22 STA 767-787<[01] R/H SHIELD FWD.OF CARGO DOOR FOUND OUT OF LIMITS PER SRM 53-00-53-1A-2.;[02] LOCATED AND DRILLED NEW SHIELD ASSY PER SRM 51-30?01;[03] REJECT: FAULT HAS 2 FAULTS PRESENT:<BR><BR>1. CORRECTIVE ACTION #1 HAS INCORRECT REFERENCE NOTED. THE AFT CARGO RIGHT HAND FWD SHIELD ASSEMBLY IS LISTED IN SRM 53-60-15-0I-1 AS DOOR SURROUND STRUCTURE. ANY LIMITS DETERMINATION IN THIS AREA SHOULD BE PER SRM 53-60-15-1A-1. AS NOTED IN SRM 51-00-04-0G-0 TABLE 2; THIS AREA IS LISTED AS PRIMARY PSE. MPM 10.03.04 STATES THAT PRIMARY PSE STRUCTURE IS RII FOR BOTH REPAIR AND INSTALLATION OPERATIONS. TO CORRECT THIS REJECT; THE REFERENCE SHOULD BE UPDATED AND THE MEASUREMENT FOR RII SHOULD BE CHANGED FROM NO TO YES.<BR><BR>2. CORRECTIVE ACTION #2 HAS INCORRECT REFERENCE FOR WORK PERFORMED.;[04] ENTERED INCORRECT SRM REFERENCE SHOULD BE SRM 53-60-15-1A-1.;[05] CORRECTIVE ACTION #2 HAS ENTERED INCORRECT SRM REFERENCE. THE CORRECT REFERENCE IS SRM 51-40-05 (FASTER HOLE SIZES).;[06] LOCATED; DRILLED; TREATED AND PRIMED SERVICEABLE SHIELD ASSEMBLY PER SRM 51-40-05; SRM 51-20-01. INSTALLED SERVICEABLE RIGHT FORWARD SHIELD ASSEMBLY PER SRM 51-40-02.