What was found
CORROSION FLOOR STRUCTURE BEAM UPPER FLANGE BS 986.5 AND LBL 43 WL 208.1 AT AFT GALLEY AREA 2023-751590<[01] TOOL USED ULTRASONIC EQUIPMENT P/N 45MG; S/N 130066401; DUE DATE 05/OCT/24;[02] TOOL USED: EDDY CURRENT FLAW DETECTOR; P/N: NORTEC 600 D; S/N: 60009161631; DUE DATE: 31-JAN-24.;[03] TOOL USED: EDDY CURRENT FLAW DETECTOR; P/N: NORTEC 600 D; S/N: 60009161631; DUE DATE: 31-JAN-24.;[04] PERFORMED PERMANENT REPAIR LOCATED ON FLOOR BEAM STRUCTURE UPPER FLANGE BS 986.5 BTW LBL40 AND LBL47 WL208.1 IAW B737-800 SRM SRM 53-70-51-2R-6 REPAIR 6 SRM 51-40-02. SEE INDIVIDUAL SIGN OFF BELOW.;[05] PERFORMED PERMANENT REPAIR LOCATED ON FLOOR BEAM STRUCTURE UPPER FLANGE BS 986.5 BTW LBL40 AND LBL47 WL208.1 IAW B737-800 SRM SRM 53-70-51-2R-6 REPAIR 6 SRM 51-40-02. SEE INDIVIDUAL SIGN OFF BELOW.<BR>CERTIFIED AS RII