What was found
CORROSION INTERCOSTAL - WEB FLOOR STRUCTURE LOCATED BS294 PLUS 13INCH LBL12 AND WL208 AT FWD GALLEY AREA 2023-756796<[01] REPLACED INTERCOSTAL - WEB FLOOR STRUCTURE AND FASTENERS LOCATED BTW BS294 TO BS312 LBL12 AND WL208 AT FWD GALLEY AREA IAW B737-700 SRM 51-10-02 Ï¿½TEM 9 AND DWG 141A5600 SHEET 1 AND 2 REV N. SEE INDIVIDUAL SIGN OFFS BELOW;[02] REPLACED INTERCOSTAL - WEB FLOOR STRUCTURE AND FASTENERS LOCATED BTW BS294 TO BS312 LBL12 AND WL208 AT FWD GALLEY AREA IAW B737-700 SRM 51-10-02 Ï¿½TEM 9 AND DWG 141A5600 SHEET 1 AND 2 REV N. SEE INDIVIDUAL SIGN OFFS BELOW COMPLETED RII